The PCU-2000 Pressure Control unit is a two-channel, patient-isolated, mains powered amplifier/interface unit for connecting one or two Millar Mikro-Tip catheters to a MDD approved pressure monitor and data acquisition system. Each channel has an electrically isolated input for patient safety. The analogue output signal level of 1V/100 mmHg is compatible with most pressure monitors and data acquisition systems including AD Instruments PowerLab.

The PCU-2000 provides electrically isolated bridge excitation and signal amplification for each channel as well as separate balance, or zero, controls. Push button switches provide calibration signals equivalent to 0, 25, 100 and 125 mmHg on each channel. A Standby/Transducer switch allows the operator to reset zero and recalibrate during a procedure with the transducer in place in the subject.

LED bar graphs visually confirm transducer functionality. Pressure input connectors are colour-coded Redel style, while pressure output connectors are 1/4-inch phone plug style. Pressure output cables are sold separately. 

PCU-2000 Features

  • CE approved
  • Patient isolated
  • Supports one dual-sensor or two single-sensor Mikro-Tip catheters
  • Line powered



PCU-2000 Specifications

Equipment Classifications                              II (USA), IIb (EU), II (Canada)
Ingress Protection                                         IP20
Type                                                           CF
Pressure Transducer Characteristics
     Transducer Sensitivity                              5 mV/V/mmHg, nominal 
     Bridge Excitation Load Resistance             1000 ohms, nominal
                                                                  350 ohms, minimum
Transducer Bridge Excitation                           5.0 VDC, nominal
Signal Input Resistance                                 50 megohm, nominal
Pressure Outputs
     Sensitivity                                              1 V/100 mmHg, nominal
     Accuracy Error Band                                <±1 mmHg or 1% of reading, whichever is greater
     Frequency Response                               DC to1000 Hz (-3 dB), minimum
     Output Resistance                                   1000 ohms, nominal
     Noise                                                     <0.3 mmHg peak-to-peak
     Zero-Offset Temperature Coefficient         <0.15 mmHg/°C
     Gain Temperature Coefficient                   <0.1 %/°C
     Balance Adjustment Range                       ±140 mmHg, nominal
Standby-Calibration Mode
     Zero Offset                                            <±1 mmHg
     Calibration Steps                                      0, 25, 100 and 125 mmHg
     Calibration Accuracy                                <± 0.5 mmHg
LED Bar Graphs
     Range                                                    -25 to 200 mmHg in 10 steps
     Resolution                                               25 mmHg
     Out of Range                                          Top light stays on at high pressures
                                                                  Bottom light turns off at low pressures
Power Supply                                               External AC/DC desktop style
     Input (Universal)                                      100 to 240 VAC, 0.3A, 50/60 Hz
     Output                                                    5 VDC/2.0 A, regulated (±5%)
     Safety Approvals                                    EN 60601-1, CSA C22.2 No. 601.1
Mechanical
     Size                                                        2.6 in. H x 6.1 in. W x 5.3 in. D
                                                                   (6.6 cm H x 15.5 cm W x 13.5 cm D)
     Weight                                                    1.1 lbs. (0.5 kg)
Environmental
     Operating                                                50° to 104°F (10° to 40°C), 30 to 75 % RH
     Transport and Storage                               -4° to 149°F (-20° to 65°C), 30 to 75% RH

Safety Protection
     Fuse                                                      Resettable, 0.4A

Note: Specifications subject to change without notice.


Mikro-Tip Catheter Pressure Interface Cables

Mikro-Tip Pressure Catheters are provided with either Viking (4-pin) or Millar Low Profile (4-pin) connectors depending on the model purchased.

Catheter models with Viking connectors may connect directly to the Pressure Control Units. Connecting the catheter with a Viking connector directly to the control unit limits access to the subject or patient.

It is recommended that an interface cable (TEC-10C) be used between the catheter and control unit. All catheters with low profile pressure connectors require an appropriate interface cable (TEC-10D) to the control unit. Each pressure channel requires a separate interface cable and control unit.





Cable Model Part Number Cable Length Catheter End Connector Type
PEC-1.5C 850-5088 1.5 ft. (46 cm) Viking
PEC-10C 850-5089 10 ft. (305 cm) Viking
PEC-4D 850-5103 4 ft. (122 cm) Low Profile
PEC-10D 850-5090 10 ft. (305cm) Low Profile
NOTE: Viking connectors are round with 4 pins. Low Profile connectors are flat with 4 pins.



TC-510 Passive Pressure Control Unit

TC-510The TC-510 Pressure Control Unit is a passive interface between the Millar Mikro-Tip catheter pressure transducer and strain gauge pressure monitors which supply bridge excitation voltage and have balance and calibration controls for full-bridge strain gauge pressure transducers.

The TC-510 has an internal calibration circuit to provide an electrical zero as well as a 100 mmHg calibration signal. The output connector is a standard 9-pin sub-D. A separate monitor interface cable is required.


Adapter/Interface Cable Ordering Information

Cable Model Part Number Cable Length Catheter End Connector Type Control Unit
Connector Type
TEC-5C 850-1118 5 ft. (152 cm) Viking Viking
TEC-10C 850-1108 10 ft. (304 cm Viking Viking
TEC-10D 850-1308 10 ft. (304 cm) Low Profile Viking
NOTE: Viking connectors are round with 4 pins. Low Profile connectors are flat with 4 pins. The above flexible cables facilitate manoeuvring the catheter during recording. They may be sterilized and permit connection of a catheter to a Pressure Control Unit located outside the sterile field.



Visit Millar Website

Single Pressure Sensor Clinical

Dual Sensor

Pressure Volume Catheters


MPVS PV Conductance System

Single Pressure Sensor Research

 Pressure Control Units

PowerLab® Data Acquisition

MPress Software


















Privacy Statement and Terms & Conditions Of Sale. Copyright © P.M.S (Instruments) Ltd 2012.     

Home | Catalogue | Vascular | Blood Pressure | ECG Products | What's New | Millar Catheters Links | Pulse Oximeters | Defibs | FAQ's | PDF Files | Contact Us