| Cardiovascular Pressure Catheters |
|
|
|
Millar Instruments manufactures and markets a
line of combination Pressure-Volume (P-V)
catheters.
These catheters combine pressure sensors and
electrodes for simultaneous high fidelity
pressure and volume measurements, enabling
minimally invasive, continuous, intra cardiac
pressure-volume analysis. P-V models feature a
high torque catheter body and range in size from
3 to 7 French in single-field or dual-field
configurations, with closed-end pigtails.
Model configurations include the availability of
a second pressure sensor, and as many as 12
electrodes. Electrode spacing varies to
accommodate a range of applications. These
catheters are warranted for five uses or sixty
days, whichever occurs first.
|
|
SPC-550-2 |
SPC-550-5 |
SPC-550-7 |
|
Part Number |
820-0011-2 |
820-0011-5 |
820-0011-7 |
|
MRI
Compatible |
No |
No |
No |
|
Catheter
Material |
Nylon |
Nylon |
Nylon |
|
Effective
Length |
125 cm |
125 cm |
125 cm |
|
French Size |
5 |
5 |
5 |
|
Number of
Sensors |
1 |
1 |
1 |
|
Sensor
Location from Tip |
Between 4th
and 5th electrode |
Between 5th
and 6th electrode |
Between 5th
and 6th electrode |
|
Tip
Characteristics |
Straight |
Straight |
Straight |
|
Pigtail |
Yes |
Yes |
Yes |
|
Electrodes |
12 |
12 |
12 |
|
Electrode
Spacing |
9 mm |
7 mm |
10 mm |
|
Field
Configuration |
Dual |
Dual |
Dual |
|
Electrode
Catheter Approach |
Standard |
Standard |
Standard |
|
Connector
Type |
Low Profile |
Low Profile |
Low Profile |
|
Reusable |
Yes |
Yes |
Yes |
|
Repairable |
No |
No |
No |

|
|
SPC-550-8 |
SPC-560-1 |
SPC-560-5 |
|
Part Number |
820-0011-8 |
815-0039-1 |
815-0039-5 |
|
MRI
Compatible |
No |
No |
No |
|
Catheter
Material |
Nylon |
Polyurethane |
Polyurethane |
|
Effective
Length |
125 cm |
125 cm |
125 cm |
|
French Size |
5 |
6 |
6 |
|
Number of
Sensors |
1 |
1 |
1 |
|
Sensor
Location from Tip |
Between 4th
and 5th electrode |
Between 4th
and 5th electrode |
Between 5th
and 6th electrode |
|
Tip
Characteristics |
Straight |
Straight |
Straight |
|
Pigtail |
Yes |
Yes |
Yes |
|
Electrodes |
8 |
12 |
12 |
|
Electrode
Spacing |
7 mm |
7 mm |
7 mm |
|
Field
Configuration |
Single |
Dual |
Dual |
|
Electrode
Catheter Approach |
Standard |
Standard |
Standard |
|
Connector
Type |
Low Profile |
Low Profile |
Low Profile |
|
Reusable |
Yes |
Yes |
Yes |
|
Repairable |
No |
No |
No |

|
|
SPC-562-1 |
SPC-570-2 |
SPC-570-7 |
|
Part Number |
820-0025-1 |
820-0009-2 |
820-0009-7 |
|
MRI
Compatible |
No |
No |
No |
|
Catheter
Material |
Polyurethane |
Polyurethane |
Polyurethane |
|
Effective
Length |
125 cm |
125 cm |
125 cm |
|
French Size |
6 |
7 |
7 |
|
Number of
Sensors |
2 |
1 |
1 |
|
Sensor
Location from Tip |
Between 4th
and 5th electrode and 5 cm proximal
to12th electrode |
Between 4th
and 5th electrode |
Between 5th
and 6th electrode |
|
Tip
Characteristics |
Straight |
Straight |
Straight |
|
Pigtail |
Yes |
Yes |
Yes |
|
Electrodes |
12 |
12 |
12 |
|
Electrode
Spacing |
7 mm |
9 mm |
10 mm |
|
Field
Configuration |
Dual |
Dual |
Dual |
|
Electrode
Catheter Approach |
Standard |
Standard |
Standard |
|
Connector
Type |
Low Profile |
Low Profile |
Low Profile |
|
Reusable |
Yes |
Yes |
Yes |
|
Repairable |
No |
No |
No |

|
|
SPC-570-9 |
SPC-572-7 |
|
Part Number |
820-0009-9 |
820-0012-7 |
|
MRI
Compatible |
No |
No |
|
Catheter
Material |
Polyurethane |
Polyurethane |
|
Effective
Length |
125 cm |
125 cm |
|
French Size |
7 |
7 |
|
Number of
Sensors |
1 |
2 |
|
Sensor
Location from Tip |
Between 4th
and 5th electrode |
Between 5th
and 6th electrode and 5 cm proximal
to12th electrode |
|
Tip
Characteristics |
Straight |
Straight |
|
Pigtail |
Yes |
Yes |
|
Electrodes |
8 |
12 |
|
Electrode
Spacing |
8.5 mm |
10 mm |
|
Field
Configuration |
Single |
Dual |
|
Electrode
Catheter Approach |
Standard |
Standard |
|
Connector
Type |
Low Profile |
Low Profile |
|
Reusable |
Yes |
Yes |
|
Repairable |
No |
No |
NOTE: These
catheters require a Pressure Control Unit and an
interface cable to your monitor. An electrode
interface cable to connect to your particular
pressure-volume data acquisition system is also
required.
 |
|

Single Pressure Sensor
Dual Sensor
Angio Catheter
Pressure Volume
Catheters
MPVS PV
Conductance System
Single Pressure
PCU-2000
Urodynamic
Catheters


|
Privacy
Statement and
Terms
& Conditions Of Sale.
Copyright
© P.M.S (Instruments) Ltd 2008.
Home |
Catalogue |
Vascular |
Blood Pressure |
ECG Products |
What's New |
Millar Catheters
Links |
Pulse Oximeters |
Defibs |
FAQ's |
PDF Files |
Contact Us
|