| Cardiovascular Pressure Catheters |
|
Millar Mikro Tip Pressure And Pressure Volume
Catheters. |
|
Millar Catheters are pressure measurement
devices which consist of a sensing element, (a
patented ultra miniature semi-conductor gauges
designed specifically for catheter transducer
applications) placed at the distal end of a
catheter, at the source of the pressure being
measured.
Essential for any study where accurate analyses
of pressures and pressure waveforms are
required, Mikro-Tip catheters provide signals
suitable for storage on high frequency response
data acquisition and computer systems. Millar
Mikro-Tip Catheters have a wide range of
applications in cardiology.
|
Mikro-Tip
catheter pressure sensors have
exceptional thermal stability and
linearity, with negligible hysteresis.
These pressure sensors provide a high
signal-to-noise ratio and good
resolution of low-level sounds and
pressures. Over-pressures of several
thousand mmHg will not damage the
sensor, and their low mass make them
insensitive to acceleration forces and
catheter whip. |
Mikro-Tip catheters offer many
advantages over conventional fluid-filled
external transducer systems, with additional
benefits specific to different applications.
However, benefits common to all types of use
are:
- Higher Frequency Response
Mikro-Tip catheters provide a frequency
response of flat to 10 kilohertz, whereas
fluid-filled systems typically have a useful
frequency range of 0 to 20 hertz because of
their low resonant frequency (25 to 35 Hz).
- No Motion Artefact
Motion Artefact is an unwanted noise on a
pressure signal caused by the movement of
the catheter.
- Position Independence
By measuring pressure through a sensor
placed directly at the source, Mikro-Tip
catheters are not affected by external
factors. Mikro-Tip catheters provide an
exact representation of the physiological
pressure changes taking place in the body
NOT of the physical characteristics of the
measurement system.
- Ease of Use
With Mikro-Tip catheters a simple
three-stage process of monitor zeroing,
monitor gain adjustment, and transducer
balancing is all this is required.
PCU 2000 Dual Channel
Patient Isolated Pressure Control System
Approved for Human Use. Single sensor Mikro-Tip®
catheters are ideal for high fidelity pressure
measurement when a lumen is not required. These
catheters range in size from 2 to 7 French, in
length from 65 to 120 cm, and in material
(either woven Dacron or polyurethane). The
smaller French sizes are suitable for paediatric
cardiology or other small vessel access.
-
Cardiovascular Mikro-Tip®
Pressure-Volume Catheters
For human use. Pressure-Volume Combination
catheters integrate pressure and volume
measurements. Pressure is measured with the
Millar Mikro-Tip® sensor while volume
measurement is achieved through the use of
electrodes. Through an impedance technique,
these electrodes detect changes in the
volume inside of a cavity such as the left
ventricle. Pressure and volume can then be
measured continuously. Such data may be used
to generate pressure-volume loops, calculate
intracavity vector-volume, measure
conductance, determine segmental
conductivity of the blood/fluid, and a host
of other parameters. Evaluation of these
parameters, in turn, can provide assessment
of fundamental mechanical properties such as
cardiac performance. A diverse mix of
standard models for human and animal use,
with or without pigtail, variable sensor and
electrode configuration and ranging in size
from 1.4 to 7 French, are available as
standard catalogue models.
-
Cardiovascular
Single Sensor Mikro-Tip® Pressure
Transducer Catheters
Approved for Human Use. Single sensor
Mikro-Tip® catheters are ideal
for high fidelity pressure measurement when
a lumen is not required. These catheters
range in size from 2 to 7 French, in length
from 65 to 120 cm, and in material (either
woven Dacron or polyurethane). The smaller
French sizes are suitable for paediatric
cardiology or other small vessel access.
-
Dual Sensor
Mikro-Tip® Catheters
Approved for Human Use. Mikro-Tip® catheters
with two pressure sensors are suitable for
high fidelity pressure gradients such as
across a valve or between chambers. Dual
sensor Mikro-Tip® catheters range in size
from 2.5 to 7 French, in length from 120 to
135 cm, and in material (either woven Dacron
or polyurethane).
-
Disposable
Angiographic Catheters
Approved for Human Use. Disposable
Mikro-Tip® angiographic catheters feature a
single pre-calibrated pressure transducer,
high-flow angiographic lumen, braided
polyurethane catheter material and open-end
pigtail for use with a guide wire. These
catheters, 105 cm in length, have a pressure
range of –50 to +300 mmHg and are available
in 5 and 6 French sizes. Disposable 6 French
models offer use of a 0.028" guide wire and
an injection flow rate equal to or greater
than 20 ml per second (H2O @ 1200 psi). The
5 French sizes allow use of a 0.025" guide
wire and an injection flow rate of equal to
or greater than 16 ml per second (H2O @ 1200
psi).
-
Ultra miniature Pressure Catheters
Non clinical Animal use only. These ultra
miniature pressure catheters were developed
for measuring pressures in small laboratory
animals. In these models, the catheter body
is smaller than the tip sensor to allow
flexibility and to minimally obstruct the
vessels or valves through which it passes.
With sensor tips Ranging in size from 1.4 to
3 French and working lengths from 50 to 140
cm.
MPVS™
Ultra miniature Single Segment
Pressure-Volume Conductance System.
Animal use only. The introduction of the
first pressure-volume catheter in Millar’s
1.4-2.0 French series revolutionized the
possibilities for conductance research in
small transgenic animals, allowing
ventricular pressure and volume measurement
in subjects as small as 16 grams. The ultra
miniature pressure sensor and smaller
flexible catheter body minimize obstruction
in small vessels and valves. These catheters
are available with one pressure sensors and
four platinum electrodes.

|
|

Single Pressure Sensor
Dual Sensor
Angio Catheter
Pressure Volume
Catheters
MPVS PV
Conductance System
Single Pressure
PCU-2000

Click to enlarge
|
Privacy
Statement and
Terms
& Conditions Of Sale.
Copyright
© P.M.S (Instruments) Ltd 2008.
Home |
Catalogue |
Vascular |
Blood Pressure |
ECG Products |
What's New |
Millar Catheters
Links |
Pulse Oximeters |
Defibs |
FAQ's |
PDF Files |
Contact Us
|